Power requirements

Horizonmacro

Horizonmacro power requirements are determined by the BTS cabinet type:

Indoor: +27 V dc, –48 V dc, 230 V ac.
Outdoor: 110 V ac single phase, 230 V ac single/3-phase.
12 carrier outdoor: 230 V ac single/3-phase.

Only –48 V dc indoor cabinets can be installed in the 12 carrier outdoor.

 Horizonmicro2 and Horizoncompact2

The Horizonmicro2 and Horizoncompact2 enclosures operate from a 88 to 265 V
ac power source.

M-Cell6

The M-Cell6 BTS cabinet can be configured to operate from either a +27 V dc or
–48 V/–60 V dc power source (indoor) or 230 V/110 V ac.


M-Cell2


The M-Cell2 BTS cabinet can be configured to operate from either a +27 V dc or
230 V/110 V ac power source.


M-Cellcity and M-Cellcity+

The M-Cellcity and M-Cellcity+ BTS enclosures operate from a 88 to 265 V ac
power source.